OMNI 504
TIME AND DATE SET
INSTRUCTIONS
1.
With
the scale turned on, press the [OMSI] key.
2.
(SEC id) will be displayed.
3.
Using
the [NET/GROSS] key and the [TARE] key, enter the number 1 six times (1 1 1 1 1
1). NOTE: The [TARE] key is the increment advance and the [NET/GROSS] key is
the position advance. With the display showing (SEC id), press the [TARE] key. The display will
show 0. Press the [TARE] key to change it to a 1. Press the [NET/GROSS] key.
The display will show 10. Press the [TARE] key to change the 0 to a 1. The
display now shows 11. Repeat these steps until “1 1 1 1 1 1” is displayed.
4.
Press
the [PRINT] key one time. The [PRINT] key has become the ENTER key.
5.
(Uid)
will be displayed. Press the [OMSI] key.
6.
(ti) will be displayed. Press the [PRINT] key and the time
will be displayed. (Hr, Min, Sec) Using the [TARE] key and the [NET/GROSS] key
as in step 3, enter the current time in six digit (24 hour) format. (IE:
9:15:30 AM = 091530; 3:25:45 PM = 152545). Press the [PRINT] key.
7.
(dt) will be displayed. Press the [PRINT] key and the date
will be displayed. (mm dd yy). Using the method used
in step 6, enter the correct date. Press the [PRINT] key.
8.