DIGI-STAR EZ 210 SCALE CALIBRATION

(USING KNOWN WEIGHT)

 

1.         Power up the scale indicator and allow it to warm up for 5 minutes.

2.         Press and hold the [NET/GROSS] key, then press and hold the [ON] key. “CAL” will appear at the top of the display in small letters. This will indicate that the scale is in the calibration mode.

3.         LANGUAGE will appear on the display, then change to “ENGLISH”.

4.         Press the [ON] key.

5.         P-ALM will appear on the display, then change to “100”.

6.         Press the [ON] key.

7.         TIME will appear on the display, then change to the current time.

8.         Press the [ON] key.

9.         DATE will appear on the screen, then change to the current date.

10.      Press the [ON] key.

11.      MARQUE will appear on the display, then change to “OFF”.

12.      Press the [ON] key.

13.      MOTION will appear on the display, then change to “OFF”.

14.      Press the [ON] key.

15.      D RATE will appear on the display, then change to “2”.

16.      Press the [ON] key.

17.      W MTHD will appear on the display, then change to “1”.

18.      Press the [ON] key.

19.      ZTRACK will appear on the display, then change to “OFF”.

20.      Press the [ON] key.

21.      The scale will display the message: “PRESS NET/GROSS FOR CALIBRATION – PRESS TARE FOR SETUP – PRESS ON TO EXIT”. Press the [NET/GROSS] key for calibration.

22.      LB-KG will appear on the display, then change to “LB”.

23.      Press the [ON] key.

24.      CAP will appear on the display, then change to “40000”.

25.      Press the [ON] key.

26.      COUNT will appear on the display, then change to “10”.

27.      Press the [ON] key.

28.      ZERO will appear on the display, then change to a number. Press the [NET/GROSS] key, then the [ZERO] key to zero balance the indicator.

29.      Press the [ON] key.

30.      ADD WT will appear on the display, then change to “0”.

31.      At this time, you will place a known weight of at least 4000 lb. on the mixer.

32.      Press the [ON] key.

33.      Enter the number of the known weight by pressing the [NET/GROSS] key to change the value of the flashing digit, and [TARE] to change the position of the flashing digit in the number.

34.      When the correct weight has been entered, press the [ON] key to enter the calibration number into the scale.