Weightronix Troubleshooting Tips

 

 

 

Troubleshooting

MODEL

PROBLEM

PROCEDURE

Model 1015

won't turn on

Check input voltage 10 to 16 volts dc. Must be negative ground system. Check keypad make sure no damage to keys.

Model 1015

won't zero /
shows err

Disconnect weigh bars,rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.

Model 1015

stuck on #

Check keypad for damaged area. make sure unit is in "gross" mode. Disconnect bars.

Model 1015

scale isn't
weighing right

Check bars. Make sure they are showing the same. Check code number in unit.

Model 1015

shows last
ingredient of reciepe

Needs atleast rev. e if not sent in. Do master reset. Need all info. Before doing master reset.

Model 600

won't turn on

Check input voltage 10 to 16 volts dc. Must be negative ground system. Check keypad make sure no damage to keys.

Model 600

won't zero /
shows err

Disconnect weigh bars,rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.

Model 600

scale isn't
weighing right

Check bars. Make sure they are showing the same. Check code number in unit.

Model 615

won't turn on

Check input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.

Model 615

won't zero /
shows err

4 bar indicators= with one bar hooked up the applied weight will show up as 4 times the weight on display.50 x 4 =200

Model 615

locked on zero

4 bar indicators= with two bars hooked up the applied weight will show up as 2 times the weight on display.

Model 615

scale isn't
weighing right

3 bar units = with one bar hooked up the applied weight will show up as 2 times the weight on the display.
50 x 2 =100

Model 615

hooking up
to rd-4000 / 6000

The RD needs software version 8.0 to run on farm units.

Model 700

won't turn on

Check input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.

Model 700

won't zero / shows err / stuck on #

Disconnect weigh bars,rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.

Model 700

scale isn't weighing right

Check bars. Make sure they are showing the same. Check code number in unit.

Model 700e

won't turn on

Check input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.

Model 700e

won't zero /
shows err /
stuck on #

Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.

Model 700e

scale isn't
weighing right

Check bars. Make sure they are showing the same. Check code number in unit.

Model 700e

hooked up to rd-712

Needs the green wire removed in the rd-712 to work correctly.

Model 715

won't turn on

Check input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.

Model 715

won't zero /
shows err /
stuck on #

Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.

Model 715

scale isn't weighing right

Check bars. Make sure they are showing the same. Check code number in unit.

Model 915

won't turn on

Check power supply. vr2

Model 915

won't zero /
shows err /
stuck on #

Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.

Model 915

scale is not
weighing right

Check bars. Make sure they are showing the same. Check code number in unit.

Model 815

scale is locked up

Check power supply voltages +8,-8,5 volts.Try using course zero pot without bars hooked up.

4-pin bars

b-c=240 / c-d=240 / b-d=480

a=shield b= red c=black d=white.

5-pin bars

a-c=350 / b-d=350 / a-b=262 / b-c=262 / c-d=262 / a-d=262

A=red / b=green / c=white / d=black / e=shield

7-pin