MODEL
|
PROBLEM
|
PROCEDURE
|
|
Model
1015
|
won't
turn on
|
Check
input voltage 10 to 16 volts dc. Must be negative ground system. Check
keypad make sure no damage to keys.
|
|
Model
1015
|
won't
zero /
shows err
|
Disconnect
weigh bars,rezero
unit. Hook one bar up and rezero unit. Do this
until bad bar appears.
|
|
Model
1015
|
stuck
on #
|
Check
keypad for damaged area. make sure unit is in
"gross" mode. Disconnect bars.
|
|
Model
1015
|
scale
isn't
weighing right
|
Check
bars. Make sure they are showing the same. Check code number in unit.
|
|
Model
1015
|
shows
last
ingredient of reciepe
|
Needs
atleast rev. e if not sent in. Do master reset.
Need all info. Before doing master reset.
|
|
Model
600
|
won't
turn on
|
Check
input voltage 10 to 16 volts dc. Must be negative ground system. Check
keypad make sure no damage to keys.
|
|
Model
600
|
won't
zero /
shows err
|
Disconnect
weigh bars,rezero
unit. Hook one bar up and rezero unit. Do this
until bad bar appears.
|
|
Model
600
|
scale
isn't
weighing right
|
Check
bars. Make sure they are showing the same. Check code number in unit.
|
|
Model
615
|
won't
turn on
|
Check
input voltage 10 to 16 volts DC. Must be negative ground system. Check
keypad make sure no damage to keys.
|
|
Model
615
|
won't
zero /
shows err
|
4
bar indicators= with one bar hooked up the applied weight will show up as
4 times the weight on display.50 x 4 =200
|
|
Model
615
|
locked
on zero
|
4
bar indicators= with two bars hooked up the applied weight will show up
as 2 times the weight on display.
|
|
Model
615
|
scale
isn't
weighing right
|
3
bar units = with one bar hooked up the applied weight will show up as 2
times the weight on the display.
50 x 2 =100
|
|
Model
615
|
hooking
up
to rd-4000 / 6000
|
The
RD needs software version 8.0 to run on farm units.
|
|
Model
700
|
won't
turn on
|
Check
input voltage 10 to 16 volts DC. Must be negative ground system. Check
keypad make sure no damage to keys.
|
|
Model
700
|
won't
zero / shows err / stuck on #
|
Disconnect
weigh bars,rezero
unit. Hook one bar up and rezero unit. Do this
until bad bar appears.
|
|
Model
700
|
scale
isn't weighing right
|
Check
bars. Make sure they are showing the same. Check code number in unit.
|
|
Model
700e
|
won't
turn on
|
Check
input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad
make sure no damage to keys.
|
|
Model
700e
|
won't
zero /
shows err /
stuck on #
|
Disconnect
weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
|
|
Model
700e
|
scale
isn't
weighing right
|
Check
bars. Make sure they are showing the same. Check code number in unit.
|
|
Model
700e
|
hooked
up to rd-712
|
Needs
the green wire removed in the rd-712 to work correctly.
|
|
Model
715
|
won't
turn on
|
Check
input voltage 10 to 16 volts DC. Must be negative ground system. Check
keypad make sure no damage to keys.
|
|
Model
715
|
won't
zero /
shows err /
stuck on #
|
Disconnect
weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
|
|
Model
715
|
scale
isn't weighing right
|
Check
bars. Make sure they are showing the same. Check code number in unit.
|
|
Model
915
|
won't
turn on
|
Check
power supply. vr2
|
|
Model
915
|
won't
zero /
shows err /
stuck on #
|
Disconnect
weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
|
|
Model
915
|
scale
is not
weighing right
|
Check
bars. Make sure they are showing the same. Check code number in unit.
|
|
Model
815
|
scale
is locked up
|
Check
power supply voltages +8,-8,5 volts.Try using course zero pot without bars hooked
up.
|
|
4-pin
bars
|
b-c=240
/ c-d=240 / b-d=480
|
a=shield
b= red c=black d=white.
|
|
5-pin
bars
|
a-c=350
/ b-d=350 / a-b=262 / b-c=262 / c-d=262 / a-d=262
|
A=red
/ b=green / c=white / d=black / e=shield
|
|
7-pin
|