OMNI 510 / 512 SCALE
CALIBRATION
1.
With
the scale turned on, press the [OMSI] key.
2.
(SEC id) will be displayed.
3.
Using
the [NET/GROSS] key, and the [TARE] key, press “1” six
times. (NOTE: the [TARE] key is the increment advance and the [NET/GROSS] key
is the position advance key.) With the display showing (SEC id), press the [TARE] key. The display now
shows “1”. Press the [NET/GROSS] key. The display now shows “10”. Press the
[TARE] key to change the zero to a 1. The display now shows “11”. Press the
[NET/GROSS] key. The display now shows “110”. Press the [TARE] key to change
the zero to a 1. Repeat these steps until “1 1 1 1 1 1” is displayed.
4.
With
six 1’s displayed, press the [PRINT] key one time. The [PRINT] key has now
become the [ENTER] key.
5.
(Uid)
will be displayed.
6.
Press
the [OMSI] key 9 times, until (AutoC) is displayed.
7.
At
(AutoC), press and hold the [PRINT] key, then press the [OMSI] key. The unit
will beep and change to a number. Release both keys. If the number displayed is
not a zero, change it to zero by pressing the [TARE] key. When changed to a
zero, press [PRINT].
8.
(cb) will be displayed.
9.
Press
the [OMSI] key 14 times, until (
10.
Press
the [PRINT] key to display (0-CAL). Press the [ZERO] key.
11.
(CAP)
will be displayed. Press [PRINT]. 40000 will be displayed. Press [PRINT].
12.
(SPAN)
will be displayed. LOWER THE WEIGHT RACK INTO THE MIXER. Press [PRINT].
13.
(40000)
is again displayed. Using the [NET/GROSS] key and the [TARE] key as step 3,
enter the value of the weight just lowered into the mixer. Press [PRINT].
14.
(Uid)
will be displayed.
15.
Press
the [NET/GROSS] key. The unit now shows the calibrated weight.
16.
Remove
the weight from the mixer. The scale should return to 0 pounds.
NOTE:
If you are using a platform scale as a reference, load the box with commodity
at step 12, assuming you have already established an empty weight for the
mixer. Enter the net value of the commodity at step 13.