CALIBRATION FOR OMNI 504 SCALE

 

1.         With the scale turned on press the [OMSI] key.

2.         (SEC id) will be displayed.

3.         Using the key pad press in the number 1 six times. It will appear as (- - - - - -)

4.         Press the [ENTER] key.

5.         (U id) will be displayed.

6.         Using the [OMSI] key press it 9 times until (AutoC) is displayed.

7.         At (AutoC), press and hold the [PRINT] key then press the [OMSI] key; unit will beep and Change to a number, release both keys. If the number displayed is not a 0 press the [0] key Then press the [ENTER] key.

8.         (cb) will be displayed. Press [OMSI] key.

9.         (dis UP) will be displayed. Press [OMSI] key.

10.      (bal) will be displayed; press [OMSI]

11.      (Ato) will be displayed; press [OMSI]

12.      (AtC) will be displayed; press [OMSI]

13.      (FS) will be displayed; press [OMSI]

14.      (FoFF) will be displayed; press[OMSI]

15.      (Fon) will be displayed; press[OMSI]

16.      (FoC) will be displayed; press [OMSI]

17.      (FP) will be displayed; press [OMSI]

18.      (FC) will be displayed; press [OMSI]

19.      (Lc) will be displayed; press [OMSI]

20.      (Unit) will be displayed; press [OMSI]

21.      (Cnt) will be displayed; press [OMSI]

22.      (CAL) will be displayed; press [ENTER] key

23.      (0-CAL) will be displayed; press [ZERO] key

24.      (CAP) will be displayed; press [ENTER].

25.      40000 will be displayed. Press [ENTER]

26.      (SPAN) will be displayed. LOWER WEIGHT RACK ON MIXER. PRESS [ENTER] key

27.      (40000) will be displayed again. Using the key pad, enter the known value, the press the [ENTER] key.

28.      Scale will display (Uid)

29.      Press [NET/GROSS] key. Unit will show the calibrated value.

30.      Remove weights, procedure is complete. Scale should go back to 0 pounds.

 

* NOTE: This procedure only applies to non-legal for trade OMNI 504 scales. If your scale is marked on the side of the case with a NTEP sticker with class III L nmax 5,000 div and a cert. # of 00-046 your scale is legal for trade.

* *NOTE: If you are using a platform scale as a reference, load your box with commodity at step number 25 assuming you have already established a empty weight on truck.