CALIBRATION FOR OMNI
504 (NTEP)
READ
THROUGH ALL INSTRUCTIONS BEFORE BEGINNING
1.
With
the scale turned on, press the [OMSI] key. (SEC id) will be displayed.
2.
Using
the key pad, press in the number 1 digit six times. It will appear as (- - - -
- -).
3.
Press
the [ENTER] key. (U id) will be displayed.
4.
Using
the [OMSI] key, press it 9 times until (AutoC) is displayed.
5.
Remove
all 8 screws from the faceplate of the scale, and remove faceplate with
attached circuit board. Locate the black button program switch labeled PROG and
depress the switch one time.
6.
The
displayed number will most likely read 9. Press the [0] key to change the 9
into a 0, then press the [ENTER] key.
7.
(cb) will be displayed. Press ENTER, 10 displayed press ENTER
8.
(diS UP) will be displayed. Press ENTER, 2 displayed, change
to a 6, press ENTER
9.
(bal) will be displayed. Press ENTER, 2 displayed press ENTER
10.
(AtO)
will be displayed. Press ENTER, 0 displayed press ENTER.
11.
(AtC)
will be displayed. Press ENTER, 50 displayed press ENTER.
12.
(FS)
will be displayed. Press ENTER, 16 displayed press ENTER.
13.
(FoFF)
will be displayed. Press ENTER, 25,000 displayed, change to 50,000, press ENTER
14.
(Fon)
will be displayed. Press ENTER, 10,000 will be displayed. change to 15,000
& press ENTER
15.
(FoC)
will be displayed. Press ENTER, 5 displayed press ENTER.
16.
(FP)
will be displayed. Press ENTER, 100,000 displayed, change to 75,000, press
ENTER
17.
(FC)
will be displayed. Press ENTER, 10 displayed press ENTER.
18.
(o-Set)
will be displayed. Press ENTER, 0 displayed press ENTER.
19.
(Lc)
will be displayed. Press ENTER, 2 displayed press ENTER.
20.
(Unit)
will be displayed. Press ENTER, 0 displayed press ENTER. ( 0 = pounds, 1 =
kilograms)
21.
(Cnt)
will be displayed. Press ENTER, random numbers displayed press ENTER.
22.
(
23.
(0-CAL)
will be displayed. Press [ZERO] key.
24.
(CAP)
will be displayed. Press ENTER, 40,000 displayed press ENTER.
25.
(SPAn)
will be displayed. Lower a known weight onto mixer of at least 4,000 pounds
or load mixer box with commodity if using a platform scale as reference. If
using a platform scale as reference do not forget to
obtain an empty weight on truck with box empty. Press ENTER.
26.
(40,000)
will be displayed again. Using key pad enter in the known value of the weight,
then press ENTER.
27.
Scale
will display (U id).
28.
Press
the [NET/GROSS] key, scale will show the calibrated weight.
29.
Lift
off weights, or empty feed box of commodity, scale should go to 0 pounds.
Note:
Shortcut at step # 5. Press and hold the [Print] key, then press and hold the
[OMSI] key, this will take you to step #6 without having to remove all the
screws.
Be sure steps 8, 12, 13, 14 and 16 are all changed as above. At step #17, with (FC)
displayed, just press the [NET/GROSS] key to exit back to gross weighing mode,
no need to continue, if you are not calibrating scale.