OMNI  504

SCALE CALIBRATION

 

NOTE:  This procedure only applies to non-legal for trade OMNI 504 scales. If your scale is marked on the side of the case with an NTEP sticker with Class III nmax 5,000 div and a cert. # of 00-046, your scale is legal for trade.

 

1.         With the scale turned on, press the [OMSI] key.

2.         (SEC   id) will be displayed.

3.         Using the keypad, press 1 six times. (- - - - - - ) will be displayed.

4.         Press the [ENTER] key.

5.         (Uid) will be displayed.

6.         Press the [OMSI] key nine times, until (AutoC) is displayed.

7.         At (AutoC), press and hold the [PRINT] key, then press the [OMSI] key. The unit will beep and display a number. Release both keys. If the number displayed is not a zero, press the [0] key, then press the [ENTER] key.

8.         (cb) will be displayed. Press the [OMSI] key.

9.         (dis  UP) will be displayed. Press the [OMSI] key.

10.      (bal) will be displayed. Press the [OMSI] key.

11.      (Ato) will be displayed. Press the [OMSI] key.

12.      (AtC) will be displayed. Press the [OMSI] key.

13.      (FS) will be displayed. Press the [OMSI] key.

14.      (FoFF) will be displayed. Press the [OMSI] key.

15.      (Fon) will be displayed. Press the [OMSI] key.

16.      (FoC) will be displayed. Press the [OMSI] key.

17.      (FP) will be displayed. Press the [OMSI] key.

18.      (FC) will be displayed. Press the [OMSI] key.

19.      (Lc) will be displayed. Press the [OMSI] key.

20.      (Unit) will be displayed. Press the [OMSI] key.

21.      (Cnt) will be displayed. Press the [OMSI] key.

22.      (CAL) will be displayed. Press the [ENTER] key.

23.      (0-CAL) will be displayed. Press the [ZERO] key.

24.      (CAP) will be displayed. Press [ENTER]. (40000) will be displayed. Press [ENTER].

25.      (SPAN) will be displayed. Lower the weight rack into the mixer. (See NOTE below). Press the [ENTER] KEY.

26.      (40000) will be displayed. Using the keypad, enter known weight just lowered into the mixer. Press the [ENTER] key.

27.      (Uid) will be displayed.

28.      Press the [NET/GROSS] key. The unit will now display the calibrated value.

29.      Remove the weight. The display should return to 0 pounds. The calibration procedure is complete.

 

NOTE:   If you are using a platform scale as a reference, load your box with commodity at step 25, assuming you have already established an empty weight.