J-STAR OMP 10 / 20 CALIBRATION

 

1.         Turn the scale on by pressing the [ON] key, then allow 5 minutes for warm up.

2.         Press the [INVENTORY] key, then the [BALANCE] key within two seconds.

3.         Add a known a weight to the scale.

4.         Press the [CLEAR] key and enter in the known weight value.

5.         Press the calibration switch located at the bottom of the scale indicator.

6.         Press the [ENTER PRESET] key then the [LOAD/UNLOAD] key.

7.         Next, using a small flat tipped screwdriver, turn the calibration control, located at the bottom of the scale indicator, until the scale display reads zero.

8.         Press the calibration switch located at the bottom of the scale indicator one more time.

 

Note: When these steps have been completed and the weight removed, the scale should settle on zero. If the scale does not return to zero, repeat steps 2 through 8 until the scale settles at zero when the calibration procedure is complete.