NAVIGATING THE OMSI CONFIGURATION MODE OF THE OMNI 504
- Press the [OMSI] key,
(SEC id) will be displayed.
- Using the key pad press
in the number 1 six times, it will appear as ------. Press the ENTER key.
- (Uid) displayed, press
ENTER, factory set at 1. Used to identify one scale or truck from
another when using the data card
option. Press ENTER.
- (ti) displayed, press
ENTER, current time displayed. The time may be changed by using the number
keys to enter in a new time in six-digit format.(24 hour format). Press
ENTER.
- (dt) displayed, press
ENTER, current date displayed. The date may be changed by using the number
keys to enter in a new date in six-digit format. Press ENTER.
- (AL) displayed, press
ENTER, 50 displayed. The Pre-Alarm weight may be changed by using the
number keys to enter in a new value. 200 seems to be the best when the
pre-alarm is used to warn operator of
nearing completion. Press ENTER.
- (rf) displayed, press
ENTER, 1 displayed. A 1 entered here will configure the system to perform
a PRINT function each time the RF Remote is activated. Press ENTER.
- (Prt) displayed, press
ENTER, 2 displayed, performs a print to printer only, 3 entered here will
perform a print to printer and data card. Press ENTER.
- (PS) displayed press
ENTER, 0 displayed for normal mode of using the I.D.#s and PRESET weights.
Press ENTER.
- (Code) displayed, press
ENTER, 111111 displayed. NOT recommended to change security code.
Press ENTER.
- (SoFt) displayed, press
ENTER, this number displayed is a view only of the version of software
used in the scale. Press ENTER
- (AutoC) displayed. If
not calibrating scale press the [NET/GROSS] to exit back to gross weighing
mode.