CALIBRATION FOR OMNI 504 SCALE
1. With the scale turned on
press the [OMSI] key.
2. (SEC id) will be displayed.
3. Using the key pad press in
the number 1 digit six times. It will appear as (------)
4. Press the [ENTER] key.
5. (U id) will be displayed.
6. Using the [OMSI] key press
it 9 times until (AutoC) is displayed.
7. At (AutoC) press and hold
the [PRINT] key then press the [OMSI] key, unit will beep and then
Change to a number, let go of both keys. If
the number displayed is not a 0 press the[ 0] key
Then press the [ENTER] key.
8. (cb) will be displayed.
Press[OMSI] key.
9. (dis UP) will be
displayed. Press[OMSI]key.
10.(bal) displayed press
[OMSI]
11. (Ato) dispalyed press
[OMSI]
12. (AtC) displayed press
[OMSI]
13. (FS) displayed press [OMSI]
14. (FoFF) displayed
press[OMSI]
15. (Fon) displayed
press[OMSI]
16. (FoC) displayed press
[OMSI]
17. (FP) displayed press
[OMSI]
18. (FC) displayed press
[OMSI]
19. (Lc) displayed press
[OMSI]
20. (Unit) displayed press
[OMSI]
21. (Cnt) displayed press
[OMSI]
22. (CAL) displayed press
[ENTER]key
23. (0-CAL) displayed press
[ZERO] key
24. (CAP) displayed
press[ENTER] then 40000 displayed. Press [ENTER]
25. (SPAN) displayed. LOWER
WEIGHT RACK ON MIXER. PRESS [ENTER] key
26. (40000) displayed
again.USING KEY PAD ENTER IN KNOWN VALUE, THEN PRESS
[ENTER] KEY.
27. SCALE WILL THEN GO BACK
AND DISPLAY (Uid)
28. Press [NET/GROSS] key,
unit will then show the calibrated value.
29. Lift off weights,
procedure is complete. Scale should go back to 0 pounds.
* NOTE: This procedure
only applies to non-legal for trade OMNI 504 scales. If your scale is marked on
the side of the case with a NTEP sticker
with class III L nmax 5,000 div and a cert. # of 00-046 your scale is legal for
trade.
* *NOTE: If you are using
a platform scale as a reference, load your box with commodity at step number 25
assuming you have already established a empty weight on truck.
.