DIGI-STAR EZ SERIES SCALE CALIBRATION

SHORT FORM

 

 

 

When installing any Digi-Star EZ series scale indicator you must check the indicator calibration. Since the scale systems will have either weigh bars or load cells, we will use one of two different calibration numbers.

 

To check or adjust the calibration value, it is necessary to enter the "short form" setup screen on the scale indicator.

 

To enter the short form screen:

 

 

1) Power up the indicator by pressing the [ON] button on the front of the indicator.

 

2) Wait for the "HELLO" message to leave the screen.

 

3) Press and hold the [ZERO] button, then press the [ON] button until the indicator beeps and the display flashes the word      "SETUP". (The screen will display the word SETUP for only one second and will then display a six digit number.)

 

4) The six digit number displayed at this point should be set to126040.

 

5) If it is necessary to change the value of this number follow the directions in step 6.

 

6) To change the value of the flashing digit, press the [NET/GROSS] button.

   To change the position of the flashing digit to the next digit over, press the [TARE] button.

 

7) Once the SETUP number has been verified as correct, press the [ON] button.

 

8) Next the screen will display "CAL" for approximately one second then it will display the actual calibration number.

 

9) As in step 6, if it is necessary to change the calibrationnumber you must use the [NET/GROSS] and [TARE] buttons.

 

CALIBRATION VALUES

LOAD CELL               WEIGH BAR

 16000                  33330

 

10) To enter the new value and exit the setup screen simply press     the [ON] button.