DIGI-STAR EZ SERIES SCALE CALIBRATION

SHORT FORM

 

When installing any Digi-Star EZ series scale indicator, you must check the indicator calibration. Since the scale system will have either weigh bars or load cells, we will use one of two calibration numbers.

 

To check or adjust the calibration value, it is necessary to enter the “Short Form” setup screen on the scale indicator.

 

1.         Power up the indicator by pressing the [ON] key.

2.         Wait for the “HELLO” message to leave the display screen.

3.         Press and hold the [ZERO] key, then press the [ON] key until the indicator beeps and the display flashes the word “SETUP”. (SETUP will be displayed for one second, then be replaced with a six digit number.)

4.         The six digit number displayed should be: 126040.

5.         If it is necessary to change the value of this number, follow the directions in the next step.

6.         To change the value of the flashing digit, press the [NET/GROSS] key. To change the position of the flashing digit, press the [TARE] key.

7.         When the setup number has been verified as correct, press the [ON] key.

8.         CAL will appear for approximately one second, then it will display the actual calibration number.

9.         As in step 6, if it is necessary to change the calibration number, you must use the [NET/GROSS] key and the [TARE] key.

CALIBRATION VALUES

LOAD CELL

WEIGH BARS

16000

33330

 

10.      To enter the new value and exit the setup screen, press the [ON] key.