OMNI 504 SCALE INDICATOR

CHANGE WEIGHING METHOD

LOAD CELLS   -   WEIGHBARS

 

1.         With the scale turned on, press the [OMSI] key.

2.         (SEC   id) will be displayed.

3.         Using the keypad, press the 1 six times (- - - - - -) will be displayed.

4.         Press the [ENTER] key. (Uid) will be displayed.

5.         Press the [OMSI] key 9 times until (AutoC) is displayed.

6.         At (AutoC), press and hold the [PRINT] key, then press and hold the [OMSI] key. The unit will beep, then change to a number. Release of both keys. The number displayed will be a 0 or a 9. If changing from load cells to weighbars, press 2. press the [ENTER] key two times. (0-CAL) will now be displayed. Press the [ZERO] key. (Uid) will be displayed. Press the [NET/GROSS] key to return to weighing mode. The scale is now calibrated for weighbars. If changing from weighbars to load cells, enter a 1 at (AutoC) and follow the same procedure just described.

 

AutoC 0:

Zero is used by the AutoC selection in the OMSI mode to enter the manual calibration mode.

AutoC 1:

Preset calibration for four 30K load cells with a system capacity of 40,000 lbs.